Characteristics |
PVI-CENTRAL-50 w/transformer |
Input Parameters |
|
Maximum recommended PV power (kWp), Total
(master slave mode) Per Channel (multi-master mode) |
57.50 |
Absolute maximum input voltage (Vdc) |
600 |
MPPT input voltage range Vdc |
300-600 (400 nominal) |
Maximum input current (Adc), Master-slave mode
Multi-master mode (per module)
|
160.00 |
Input Reflected Ripple voltage |
< 3% |
Number of DC inputs available (multi-master
configuration)
|
1 |
Input overvoltage protections |
1 |
Output Parameters |
|
Nominal AC Output Power (kW) |
52.00 |
Nominal AC Output Current (Arms)
208 Vac version
480 Vac version |
140.00
60.00
|
AC Output Voltage range (Vrms) |
3 x 208 +/-10% or 3x480 +/-10% |
Nominal AC Frequency (Hz) |
50 / 60 |
Power Factor |
1 (@ Pac nominal) |
AC Current Harmonics (THD%) |
< 3% (@ Pac nominal) |
Inverter Switching Frequency (kHz) |
18 |
AC side overvoltage protection |
Yes |
Conversion Efficiency |
|
Peak Efficiency % (@ Vin nom) |
96.3% |
CEC Efficiency % (@ Vin nom) 208 |
95% |
CEC Efficiency % (@ Vin nom) 480 |
95% |
Environmental Parameters |
|
Environmental Protection Degree |
NEMA 2/NEMA 3R |
Operating Temperature Range |
-10°C...+50°C |
Relative Humidity (non-condending) |
< 95% |
General Data |
|
Auxlilary Voltages Consumption (W) |
<0.2% of PACnom |
Night time losses (W) |
<40W |
Local Communication |
1x RS485 + 1x RS485 (dedicated to String combiner-Box) |
Remote Communication (optional) |
Aurora Easy Control (Dial-Up, ISDN, Ethernet, DSL, GSM) |
User Interface |
2-lines Display (on each inverter module) |
Mechanical Characteristics |
|
Dimensions (WxHxD) (mm) (*) Output Air conduit
not included |
1250 x 1570(*) x 810/49.2”x61.8”x31.8” |
Overall Weight (kg) |
800/1760 |
55kW module Weight (kg) |
65/143 |
Required Ambient Air Cooling Flow |
1500m3/h/2700CFM |
Approvals |
|
EMC |
FCC part 15 |
CE Compliance |
Yes |
Grid connection (pending) |
DK5940 Ed. 2.2, VDEW, UL1741, RD1663/2000 |