Magnetek’s PVI-CENTRAL-200/200-TL grid-tied systems are designed for large solar applications such as “big box” retail, office buildings, industrial facilities or ground mount installations. Harvest more green with Aurora’s Maximum Power Point Tracking (MPPT) algorithm that maximizes energy produced under varying light conditions. The inverter’s Insulated Gate Bi-polar Transistors (IGBTs) reduce thermal energy losses for optimum performance.

These commercial-grade inverters feature scalability in a common-enclosure package that is delivered pre-configured and pre-tested. In addition to reducing on-site installation wiring and testing, this industry-leading technology provides cost-effective solutions with smaller footprints and increased reliability.


PVI-Aurora_200

Brochure

 

Applications flexibility is further enhanced by the availability of models with and without isolation transformers that are self contained within the inverter rack.

The development of the PVI-200/200-TL was in response to the rapidly growing global demand for environmentally friendly power sources. Magnetek’s inverters deliver a unique combination of efficiency, flexibility and redundancy to the renewable energy market, demonstrating our ongoing commitment to world-class energy solutions.

Maximize power harvest

  • High conversion efficiency (CEC efficiency 96%) for maximum power harvest
    Wide operating voltage range of 330-600 Vdc increases energy collected
  • Self-tuning MPPT power curve optimizes energy harvest
  • Multiple input MPPT through modular design for array efficiency

Flexible configuration

  • Independent modules are configurable in multi-master mode or master-slave mode, providing power redundancy
  • Optional module grounding of (+) leg for application flexibility

Low installation and maintenance costs

  • Module design offers unobstructed front access to modules and power boards for quick inverter installs and simplified maintenance
  • Reduced wiring for ease of installation
  • Hot-swappable module replacement simplifies maintenance

Extended performance

  • A broad range of communications options: dial up, ISDN, Ethernet, DSL, GSM, and the optional FlyBy Communication System hardware/software, for instant access to system status
  • Reduced sensitivity to a single fault; in case of a component fault, the system continues operating derated to 150kW
  • Five-year warranty extendable to 20 years
 

  Characteristics

PVI-CENTRAL-200 w/transformer PVI-CENTRAL-200-TL
w/o transformer

  Input Parameters

 

  Maximum recommended PV power (kWp),   Total (master slave mode) Per Channel   (multi-master mode)

230.00
57.50
230.00
57.50

  Absolute maximum input voltage (Vdc)

600 600

  MPPT input voltage range Vdc

330-600 (400 nominal) 330-600(400 nominal)

  Maximum input current (Adc), Master-slave   mode Multi-master mode (per module)

606
151
606
151

  Input Reflected Ripple voltage

< 3% < 3%

  Number of DC inputs available
  (multi-masterconfiguration)

4 4

  Input overvoltage protections

4 ( 1 of each input) 4 ( 1 of each input)

  Output Parameters

 

  Nominal AC Output Power (kW)

208.00 208.00

  Nominal AC Output Current (Arms)
  208 Vac version
  480 Vac version


560.00
240.00


560.00
N/A

  AC Output Voltage range (Vrms)

3 x 208 +/-10% or 3x480 +/-10% 3 x 208+/-10%

  Nominal AC Frequency (Hz)

50 / 60 50 / 60

  Power Factor

1 (@ Pac nominal) 1 (@ Pac nominal)

  AC Current Harmonics (THD%)

< 3% (@ Pac nominal) < 3% (@ Pac nominal)

  Inverter Switching Frequency (kHz)

18 18

  AC side overvoltage protection

Yes Yes

  Conversion Efficiency

 

  Peak Efficiency % (@ Vin nom)

96.3% 97.42%

  CEC Efficiency % (@ Vin nom) 208

96% 96%

  CEC Efficiency % (@ Vin nom) 480

96% N/A

  Environmental Parameters

 

  Environmental Protection Degree

NEMA 2/NEMA 3R NEMA 2/NEMA 3R

  Operating Temperature Range

-10°C...+50°C -10°C...+50°C

  Relative Humidity (non-condending)

< 95% < 95%

  General Data

 

  Auxlilary Voltages Consumption (W)

<0.2% of PACnom <0.2% of PACnom

  Night time losses (W)

<40W <40W

  Local Communication

1x RS485 + 1x RS485 (dedicated to String combiner-Box) 1x RS485 + 1x RS485 (dedicated to String combiner-Box)

  Remote Communication (optional)

Aurora Easy Control (Dial-Up, ISDN, Ethernet, DSL, GSM) Aurora Easy Control (Dial-Up, ISDN, Ethernet, DSL, GSM)

  User Interface

2-lines Display (on each inverter module) 2-lines Display (on each inverter module)

  Mechanical Characteristics

 

  Dimensions (WxHxD) (mm) (*) Output Air   conduit not included

1250 x 2100(*) x 810/49.2”x82.6”x31.8” 1250 x 1570(*) x 810/49.2”x82.6”x31.8”

  Overall Weight (kg)

1200/2640 780/1716

  55kW module Weight (kg)

65/143 65/143

  Required Ambient Air Cooling Flow

4000m3/h/7200CFM 4000m3/h/7200CFM

  Approvals

 

  EMC

FCC part 15 FCC part 15

  CE Compliance

Yes Yes

  Grid connection (pending)

DK5940 Ed. 2.2, VDEW, UL1741, RD1663/2000 DK5940 Ed. 2.2, VDEW, UL1741, RD1663/2000
 
 
  TERMS & CONDITIONS PRIVACY STATEMENT SALES & WARRANTY TERMS
© 2008 MAGNETEK, INC.

Overview | Solar Products | Wind Products | Fuel Cell Products | Manuals | Brochures
Literature Request | News | Events | Technical Services | Downloads | Magnetek | Contact Us